# IMU System Integration Tests
|
||||||
|
|
||||||
|
This document describes integration tests for the IMU data pipeline (IMU reader ESP32, Lifecycle MITM node, Database writer node).
|
||||||
|
These tests will verify end-to-end functionality from ESP32 sensor data to database storage.
|
||||||
|
|
||||||
|
## Test Overview
|
||||||
|
|
||||||
|
The integration tests validate the complete flow through the main components:
|
||||||
|
1. ESP32 MPU6886 Sensor - Data fetching and transmission (MQTT or Serial)
|
||||||
|
2. ROS2 Lifecycle Node - Message reception from ESP and forwarding to database writer
|
||||||
|
3. IMU Database Writer Node - Database storage
|
||||||
|
|
||||||
|
## Test Environment Setup
|
||||||
|
|
||||||
|
### Prerequisites
|
||||||
|
|
||||||
|
- ESP32 with MPU6886 sensor configured and flashed
|
||||||
|
- PostgreSQL database running (can be ran using dockerfile documented in the [README](/README.md))
|
||||||
|
- ROS2 workspace built and sourced
|
||||||
|
- if testing MQTT mode, MQTT broker running
|
||||||
|
- if testing Serial mode, Serial port access
|
||||||
|
|
||||||
|
### Configuration Files
|
||||||
|
|
||||||
|
- `src/config.toml` - Database connection parameters
|
||||||
|
- `IMU/sdkconfig` - Serial/MQTT mode selection and network settings
|
||||||
|
|
||||||
|
---
|
||||||
|
|
||||||
|
## Integration Test Cases
|
||||||
|
|
||||||
|
### Test 1: Database Writer Persistence Verification
|
||||||
|
|
||||||
|
> Verify that the Database Writer node correctly saves data to the PostgreSQL database when
|
||||||
|
> IMU messages are received.
|
||||||
|
|
||||||
|
#### Test Setup
|
||||||
|
|
||||||
|
1. Start PostgreSQL database (docker compose up)
|
||||||
|
2. Verify database connection, if incorrect change settings settings in `src/config.toml`
|
||||||
|
3. Clear or note the current state of the IMU data table
|
||||||
|
4. Launch the Database Writer node:
|
||||||
|
```bash
|
||||||
|
ros2 run g2_2025_imu_reader_pkg g2_2025_imu_database_writer_node
|
||||||
|
```
|
||||||
|
|
||||||
|
#### Test Procedure
|
||||||
|
|
||||||
|
1. Query the database for initial row count
|
||||||
|
```sql
|
||||||
|
SELECT COUNT(*) FROM imu_data;
|
||||||
|
```
|
||||||
|
|
||||||
|
2. Use ROS2 CLI to publish IMU data
|
||||||
|
```bash
|
||||||
|
ros2 topic pub --once /imu_data sensor_msgs/msg/Imu "{
|
||||||
|
linear_acceleration: {x: 0.5, y: 0.6, z: 9.8},
|
||||||
|
angular_velocity: {x: 0.1, y: 0.2, z: 0.3}
|
||||||
|
}"
|
||||||
|
```
|
||||||
|
|
||||||
|
3. Query the database for new entries
|
||||||
|
```sql
|
||||||
|
SELECT * FROM imu_data ORDER BY timestamp DESC LIMIT 1;
|
||||||
|
```
|
||||||
|
|
||||||
|
4. Send 10 messages with varying data
|
||||||
|
```bash
|
||||||
|
for i in {1..10}; do
|
||||||
|
ros2 topic pub --once /imu_data sensor_msgs/msg/Imu "{
|
||||||
|
linear_acceleration: {x: $(echo "scale=2; $i * 0.1" | bc), y: 0.0, z: 9.8},
|
||||||
|
angular_velocity: {x: 0.0, y: 0.0, z: 0.0}
|
||||||
|
}"
|
||||||
|
sleep 0.5
|
||||||
|
done
|
||||||
|
```
|
||||||
|
|
||||||
|
5. Confirm all 10 messages were persisted
|
||||||
|
```sql
|
||||||
|
SELECT COUNT(*) FROM imu_data WHERE timestamp > (NOW() - INTERVAL '1 minute');
|
||||||
|
```
|
||||||
|
|
||||||
|
#### Expected Results
|
||||||
|
|
||||||
|
- [ ] Each published message creates one database row
|
||||||
|
- [ ] Linear acceleration values (x, y, z) match published data
|
||||||
|
- [ ] Angular velocity values (x, y, z) match published data
|
||||||
|
- [ ] Timestamps are automatically generated and sequential
|
||||||
|
- [ ] No data loss occurs
|
||||||
|
|
||||||
|
### Test 2: Lifecycle Node Message Forwarding
|
||||||
|
|
||||||
|
> Verify that the Lifecycle Node correctly receives IMU data from either Serial or MQTT sources and
|
||||||
|
> forwards it to the `imu_data` topic for consumption by the Database Writer.
|
||||||
|
|
||||||
|
#### Test Setup
|
||||||
|
|
||||||
|
1. Ensure ROS2 environment is sourced
|
||||||
|
2. Launch the Lifecycle Node and Database Writer Node:
|
||||||
|
```bash
|
||||||
|
ros2 run g2_2025_imu_reader_pkg g2_2025_lifecycle_node
|
||||||
|
ros2 run g2_2025_imu_reader_pkg g2_2025_imu_database_writer_node
|
||||||
|
```
|
||||||
|
4. Monitor the `imu_data` topic:
|
||||||
|
```bash
|
||||||
|
ros2 topic echo /imu_data
|
||||||
|
```
|
||||||
|
|
||||||
|
#### Test Procedure - Serial Mode
|
||||||
|
|
||||||
|
1. Configure ESP32 for Serial Output:
|
||||||
|
- Ensure `CONFIG_ENV_MQTT_ENABLED` is not defined in ESP32 sdkconfig
|
||||||
|
- Flash ESP32 with serial configuration
|
||||||
|
|
||||||
|
2. Connect ESP32 via Serial:
|
||||||
|
- Connect ESP32 to computer via USB
|
||||||
|
- Identify serial port (e.g., `/dev/ttyUSB0` on Linux)
|
||||||
|
- Configure lifecycle node to read from this serial port
|
||||||
|
|
||||||
|
3. Verify Data Flow:
|
||||||
|
- Observe lifecycle node logs for incoming serial data
|
||||||
|
- Confirm `ros2 topic echo /imu_data` displays messages
|
||||||
|
- Verify message fields match ESP32 output:
|
||||||
|
- `linear_acceleration.x/y/z` matches `accel.x/y/z`
|
||||||
|
- `angular_velocity.x/y/z` matches `gyro.x/y/z`
|
||||||
|
|
||||||
|
4. Verify Database storage:
|
||||||
|
- Check database for new entries
|
||||||
|
- Confirm values match ESP32 sensor readings
|
||||||
|
|
||||||
|
#### Test Procedure - MQTT Mode
|
||||||
|
|
||||||
|
1. Start MQTT Broker:
|
||||||
|
```bash
|
||||||
|
mosquitto -v
|
||||||
|
```
|
||||||
|
|
||||||
|
2. **Configure ESP32 for MQTT Output**:
|
||||||
|
- Enable `CONFIG_ENV_MQTT_ENABLED` in ESP32 sdkconfig
|
||||||
|
- Configure MQTT broker URI (`mqtt://192.168.1.100:1883`)
|
||||||
|
- Set MQTT topic (`CONFIG_MQTT_TOPIC = "imu/data"`)
|
||||||
|
- Configure WiFi credentials
|
||||||
|
- Flash ESP32 with MQTT configuration
|
||||||
|
|
||||||
|
3. Verify MQTT Publishing:
|
||||||
|
- Subscribe to MQTT topic to confirm ESP32 is publishing:
|
||||||
|
```bash
|
||||||
|
mosquitto_sub -h localhost -t "imu/data" -v
|
||||||
|
```
|
||||||
|
- Expected MQTT payload format:
|
||||||
|
```json
|
||||||
|
{"accel":{"x":0.123,"y":0.456,"z":9.800},"gyro":{"x":0.012,"y":0.023,"z":0.034},"Temp":25.50}
|
||||||
|
```
|
||||||
|
|
||||||
|
4. Configure Lifecycle Node for MQTT:
|
||||||
|
- Set lifecycle node to subscribe to MQTT broker and topic
|
||||||
|
- Restart lifecycle node with MQTT configuration
|
||||||
|
|
||||||
|
5. Verify Data Flow:
|
||||||
|
- Observe lifecycle node logs for incoming MQTT messages
|
||||||
|
- Confirm `ros2 topic echo /imu_data` displays messages
|
||||||
|
|
||||||
|
6. Verify Database storage:
|
||||||
|
- Check database for continuously arriving data
|
||||||
|
- Confirm timestamps are recent and sequential
|
||||||
|
|
||||||
|
#### Expected Results
|
||||||
|
|
||||||
|
**Serial Mode:**
|
||||||
|
- [ ] Lifecycle node successfully reads JSON-formatted messages from serial port
|
||||||
|
- [ ] Messages are parsed and converted to `sensor_msgs/msg/Imu` format
|
||||||
|
- [ ] All IMU data fields are correctly mapped
|
||||||
|
- [ ] Messages are published to `/imu_data` topic
|
||||||
|
- [ ] Database writer receives and persists data
|
||||||
|
|
||||||
|
**MQTT Mode:**
|
||||||
|
- [ ] Lifecycle node successfully subscribes to MQTT broker
|
||||||
|
- [ ] MQTT messages are received and parsed
|
||||||
|
- [ ] Messages are converted to `sensor_msgs/msg/Imu` format
|
||||||
|
- [ ] All IMU data fields are correctly mapped
|
||||||
|
- [ ] Messages are published to `/imu_data`
|
||||||
|
- [ ] Database writer receives and persists data
|
||||||
|
|
||||||
|
### Test 3: ESP32 Data Format Validation
|
||||||
|
> Verify that the ESP32 correctly formats and transmits IMU data in both Serial
|
||||||
|
> and MQTT modes according to the expected JSON schema.
|
||||||
|
|
||||||
|
#### Test Setup
|
||||||
|
|
||||||
|
1. ESP32 with MPU6886 sensor properly wired and powered
|
||||||
|
2. IMU sensor calibrated (100 samples for gyro and accel)
|
||||||
|
3. Serial terminal or MQTT subscriber ready to capture output
|
||||||
|
|
||||||
|
#### Data Quality Checks
|
||||||
|
|
||||||
|
- [ ] Accelerometer Z-axis reads ~9.8 (m/s)^2 when device is stationary and level
|
||||||
|
- [ ] Gyroscope values near zero when device is stationary
|
||||||
|
- [ ] Temperature reading is within expected range
|
||||||
|
- [ ] No NaN or Inf values in output
|
||||||
|
- [ ] Calibration offsets are properly applied
|
||||||
|
|
||||||
|
---
|
||||||
|
|
||||||
|
## End-to-End Integration Test
|
||||||
|
|
||||||
|
**Objective**: Validate complete system integration from ESP32 sensor to database persistence.
|
||||||
|
|
||||||
|
### Test Setup
|
||||||
|
|
||||||
|
1. Clean database state (truncate IMU data table)
|
||||||
|
2. Start PostgreSQL database
|
||||||
|
3. Start MQTT broker (for MQTT test variant)
|
||||||
|
4. Launch all ROS2 nodes:
|
||||||
|
- Lifecycle node
|
||||||
|
- Database writer node
|
||||||
|
5. Power on and connect ESP32
|
||||||
|
|
||||||
|
### Test Procedure
|
||||||
|
|
||||||
|
1. System Initialization:
|
||||||
|
- Verify all nodes are running and healthy
|
||||||
|
- Check lifecycle node is connected to data source (Serial/MQTT)
|
||||||
|
- Confirm database writer node is subscribed to `/imu_data`
|
||||||
|
|
||||||
|
2. Data Flow Verification:
|
||||||
|
- Let system run for 2 minutes
|
||||||
|
- Monitor ROS2 topics:
|
||||||
|
```bash
|
||||||
|
ros2 topic hz /imu_data
|
||||||
|
ros2 topic bw /imu_data
|
||||||
|
```
|
||||||
|
|
||||||
|
3. **Database Query**:
|
||||||
|
```sql
|
||||||
|
SELECT COUNT(*) FROM imu_data WHERE timestamp > (NOW() - INTERVAL '2 minutes');
|
||||||
|
SELECT
|
||||||
|
AVG(linear_accel_z) as avg_accel_z,
|
||||||
|
AVG(angular_vel_x) as avg_gyro_x,
|
||||||
|
MIN(timestamp) as first_sample,
|
||||||
|
MAX(timestamp) as last_sample
|
||||||
|
FROM imu_data
|
||||||
|
WHERE timestamp > (NOW() - INTERVAL '2 minutes');
|
||||||
|
```
|
||||||
|
|
||||||
|
4. Physical Movement Test:
|
||||||
|
- Pick up ESP32 and rotate it
|
||||||
|
- Observe changes in database values
|
||||||
|
- Verify accelerometer and gyroscope values change
|
||||||
|
|
||||||
|
5. Stress Test:
|
||||||
|
- Let system run for 30 minutes
|
||||||
|
- Check for memory leaks or connection drops
|
||||||
|
- Verify continuous data storage
|
||||||
|
|
||||||
|
### Expected Results
|
||||||
|
|
||||||
|
- [ ] Data flows from ESP32 -> Lifecycle Node -> Database Writer -> PostgreSQL
|
||||||
|
- [ ] Publishing rate at `/imu_data`
|
||||||
|
- [ ] Database receives ~240 rows in 2 minutes
|
||||||
|
- [ ] Average Z-axis acceleration is ~9.8 (m/s)^2 during stationary periods
|
||||||
|
- [ ] Physical movements are reflected in database values
|
||||||
|
- [ ] No data loss over extended operation (30 minutes)
|
||||||
|
- [ ] All components remain stable without crashes
|
||||||
|
|
||||||
|
## Test Execution Checklist
|
||||||
|
|
||||||
|
### Pre-Test Verification
|
||||||
|
- [ ] PostgreSQL database is running and accessible
|
||||||
|
- [ ] Database schema is created (IMU data table exists)
|
||||||
|
- [ ] ROS2 workspace is built and sourced
|
||||||
|
- [ ] ESP32 firmware is flashed with correct configuration
|
||||||
|
- [ ] MQTT broker is running
|
||||||
|
- [ ] Serial port permissions are correct
|
||||||
|
|
||||||
|
### During Test
|
||||||
|
- [ ] Monitor node logs for errors or warnings
|
||||||
|
- [ ] Check ROS2 topic publishing rates
|
||||||
|
- [ ] Verify database connection remains active
|
||||||
|
- [ ] Observe IMU data values
|
||||||
|
|
||||||
|
### Post-Test Analysis
|
||||||
|
- [ ] Review test results and logs
|
||||||
|
- [ ] Document any failures or anomalies
|
||||||
|
- [ ] Clean up test data if necessary
|
||||||
@@ -10,3 +10,14 @@ services:
|
|||||||
- POSTGRES_DB=grades
|
- POSTGRES_DB=grades
|
||||||
ports:
|
ports:
|
||||||
- "5432:5432"
|
- "5432:5432"
|
||||||
|
mosquitto:
|
||||||
|
image: eclipse-mosquitto
|
||||||
|
container_name: mosquitto
|
||||||
|
restart: unless-stopped
|
||||||
|
ports:
|
||||||
|
- "1883:1883"
|
||||||
|
- "9001:9001"
|
||||||
|
volumes:
|
||||||
|
- ./mosquitto/config:/mosquitto/config
|
||||||
|
- ./mosquitto/data:/mosquitto/data
|
||||||
|
- ./mosquitto/log:/mosquitto/log
|
||||||
|
|||||||
Reference in New Issue
Block a user